HEWI active+ Push/pull handle set


111PDDG02

Picture shows item in colour 99 (pure white)
 
 

Product information

  • made of high-quality polyamide in HEWI colour 98 (Signal white), with effective, antimicrobial microsilver
  • handle ø 33 mm, lower plate section of metal with poly. caps, plate thickness in lock cylinder area 13.5 mm
  • supplied with screws and square spindle
  • operation in the direction of door opening: Push
  • operation in the opposite direction: Pull

Attention:
  • maximum nut pivot angle of 40°
  • unsuitable for inactive leafs
  • suitabale for use in inner- and protected outer areas

Technical specifications

Material and colour
Colour
98

Certificates

  • DIN 18040-1
  • "Ü" sign fire door fitting
  • EN 179
  • Fire protection
  • HEWI active+

Downloads

HEWI colour chart
Certificates lock manufacturers DIN EN 179
Product Data Sheet
Tender specifications
Download everything

Ordering information

Ordering information:
  • Order no.
  • Colour
  • Keyway: PZ, KABA or BL
  • Square: 8 mm or 9 mm
  • Door thickness
  • Measurement xa/xi (when executed ..18..)
  • door Opening direction (DIN)
  • Lock manufacturers: Fuhr, KFV, BKS
  • Distance: 72, 92 or 98.5 mm
other distances (for example, for Switzerland and Austria) on request.

Classification

Classification
spindle 8 mm - no classification
spindle 9 mm
Designed and tested for projects, classification to EN 179
Category of use: Class 3
Durability: Class 7
Door mass: Class 6
Use on smoke/fire doors: Class 0, A or B
Safety - personal security: Class 1
Corrosion resistance: Class 3
Security - burglary protection: Class 2
Projection of operating element: Class 1
Type of operation: B
Field of door application: Class A, B, C or D

The classification results only in connection with the lock according to EN 179, for example, BKS, Fuhr or Fliether The selected combinations are assigned freely and do not have to take on a lock manufacturer.
For more information, contact HEWI or the lock manufacturer!
I agree

This website uses cookies to allow you to use the website to the optimum. Confirm that you agree to the use of the cookies by continuing to navigate through our website.

> Find out more

Please enter the email address by which you're registered here at HEWI.
We'll send you an email with instructions on how to change your password.
Request for password change failed. Reasons for this could be:
  1. The e-mail address is not registered.
  2. You have recently requested a password change. It must be at least an hour before you can perform the Forgot Password function again.
Log In
The request to change your password has been made. You will now receive an e-mail with a link to assign a new password.